Page History: EURN Generator is not starting
Compare Page Revisions
Page Revision: Tue, 08 May 2018 14:05
If the process is not listed, try running the EURNGenerator.exe as administrator.
- Go to C:\Program Files (x86)\CAREWare\RW CAREWare Business Tier.
- Right click EURNGenerator.
- Click Properties.
- Verify there is no check box for Unblock in the bottom right corner below Advanced.
- Click Compatibility.
- Click Change settings for all users.
- Check Run this program as an administrator.
- Click Apply.
- Click OK.
- Restart the business tier service.
If the issue persists, change the value for LastEURNGeneratorID to -1.
- Go to C:\Program Files (x86)\CAREWare\RW CAREWare Business Tier.
- Right click CW Admin.
- Click Run as Administrator.
- Click Stop Server.
- Click Common Storage Settings.
- Click cmm_st_pk to set the list in alphabetical order.
- Scroll to LastEURNGeneratorID.
- Double click the field for cmm_st_number.
- Enter -1.
- Click any other box to save the value.
- Click Server Settings.
- Click Start Server.
- Verify EURNGenerator.exe (32 Bit) is listed in Processes in Task Manager.
Back to